Skip to content
Free shipping over $49Order by 3 PM ET, ships the same day 30-day returns, no restocking fee
(814) 299-9937 · Mon–Fri 9am–5pm ET
Sold out
Ray Foster Variable Speed Alloy Grinder
Ray FosterSold out

Ray Foster Variable Speed Alloy Grinder

SKU 006-0022MFR# AG05
$1,880.99 · Sold out
Ray Foster AG05 High Speed Alloy Grinder with Variable Speed Control. Fingertip speed control with a front panel mounted potentiometer. Adjustable spindle working height. Heavy duty, high torque 1/4 HP motor in a totally enclosed housing. 2.5" suction port for connection to dust collector system. Power output connection. Motor is UL-recognized and CSA-certified for electrical safety. Dimension: 10.25" W, 11.75" L, 11" H. 115 volt 50/60 Hz standard. 230 volt 50/60 Hz optional for export.

Product

Manufacturer
Ray Foster
Manufacturer #
AG05
Item code
006-0022
UPC / Barcode
AG05

Catalog path

Marketplace
Laboratory

Ordering

Status
Sold out

Other in-stock items in Lab Fabrication & Finishing Equipment

Not the same product — check the specs before you swap.

Vaniman Dust Collector Filter Bags
Vaniman
Dust Collector Filter Bags
2 packs
In stock
from $47.00
Handler Two Flask Compress
Handler
Two Flask Compress
007-0123
In stock
15 sold this month
$196.80
RMH3 Dental Round Vibrator
RMH3 Dental
Round Vibrator
105-0009
In stock
$71.18
Lang Aquapres High Capacity Hydraulic Pressure Curing Unit
Lang Dental
Lang Aquapres High Capacity Hydraulic Pressure Curing Unit
045-0057
In stock
$387.70

Questions

What is Ray Foster Variable Speed Alloy Grinder used for?

Ray Foster AG05 High Speed Alloy Grinder with Variable Speed Control.

When does it ship?

In-stock orders placed before 3 PM ET ship the same day. An item we don't keep on the shelf shows its own ship-by date on its page, and you can cancel it for a full refund until it ships.Ground shipping is free over $49.

About lathes

A dental lab lathe spins the wheels, cones and buffs used for polishing; removable prostheses are mostly polished by laboratory staff on a lathe. One published sequence polishes first with pumice on a wet felt cone and then with rouge on a soft cloth wheel for the final shine.

This shelf holds the bench machines of a dental laboratory: lathes, model trimmers, vibrators, mixers, and casting and polishing units. A cast is a life-size likeness formed from a material poured into an impression. Polishing is the act of making a denture or casting smooth and glossy, usually by friction.

A study of dental laboratories lists finishing crowns, bridges and partial dentures among its noisiest work, and names vibrators, polishing equipment and sandblasters as sources of high sound levels.

How the machines differ
  • Lathes — Spins the wheels, cones and buffs used for polishing; the CDC lists lathes among the items to be cleaned and disinfected between patients.
  • Lab Vibrators — Shakes the mix into the impression after it has been mixed.
  • Mixing Equipment — Blends powder and water, under vacuum, before the mix is poured.
  • Electro-Polishing Equipment — Brightens metal by removing a thin layer electrolytically, where a lathe polishes by friction.
  • Casting Units — Fills a mould with molten material, where the other machines here shape or finish a solid one.
  • Casting Machine Parts — The parts of a casting machine, where casting units are the machines.
  • Filters — Air filters for vacuum mixers and filter parts for a casting machine.
  • General Repair & Replacement Parts — Chucks, spindles, vacuum mixer parts, O-rings, fuses and regulators.
  • Model Trimmers — Wet and dry model trimmers and arch trimmers, with their discs and parts.
  • Mixing Bowls & Lab Vessels — The bowls, paddles and lids of a vacuum mixer, where mixing equipment is the mixer.

The shelf also holds model trimmers; no source on our allowed list describes them, so this guide does not.

What to look at when choosing

Air in the mix: the strength, hardness and abrasion resistance of a gypsum cast are affected by the number and size of the voids in it.

Surface after polishing: studies cited in the denture literature put the acceptable roughness of a hard surface in the mouth at no more than 0.2 micrometres.

The CDC reports that dental laboratory technicians can breathe in crystalline silica dust when mixing powders, removing castings from moulds, grinding and polishing castings and porcelain, and blasting with silica sand.

Cleaning between cases: the CDC notes that pressure pots and water baths are particularly susceptible to contamination and should be cleaned and disinfected between patients.

Sources: The Glossary of Prosthodontic Terms, 9th edition (J Prosthet Dent 2017) · Assessment of hearing performance of dental technicians due to the professional noise exposure (BMC Oral Health 2023) · Rao et al. 2015, Surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques (J Indian Prosthodont Soc) · CDC, Guidelines for Infection Control in Dental Health-Care Settings, 2003 (MMWR 52 RR-17) · A new dental casting technique for production of void-free dental models (Eur Oral Res 2020) · CDC, Silicosis in Dental Laboratory Technicians, Five States, 1994-2000 (MMWR 53(09))