Skip to content
Free shipping over $49Order by 3 PM ET, ships the same day 30-day returns, no restocking fee
(814) 299-9937 · Mon–Fri 9am–5pm ET
Sold out
Solmetex Hg5 Collection Container with Recycle Kit
SolmetexSold out

Solmetex Hg5 Collection Container with Recycle Kit

SKU 115-0009MFR# HG5-002CR
$407.89 · Sold out
Hg5 (CC) Collection Container with Recycle Kit. Provides the Container and Packaging necessary to ship the separated amalgam to a certified recycler. It works as part of the HG5 amalgam separator system that is designed to achieve an environmentally sound solution to prevent amalgam from dental restorations from entering the public water system. Please check for compatibility. Non-Returnable.

Product

Manufacturer
Solmetex
Manufacturer #
HG5-002CR
Item code
115-0009

Catalog path

Marketplace
Clinical
Category
Evacuation

Ordering

Status
Sold out

More from Amalgam Separators

In stock in the same subcategory. Not the same product — check the specs before you swap.

View all 8
RMH3 Dental Saliva Ejectors, 15 cm
RMH3 Dental
Saliva Ejectors, 15 cm
6 styles · 2 packs
In stock
2,202 sold this month
from $3.04
RMH3 Dental Aspirator Tips
RMH3 Dental
Aspirator Tips
3 sizes
In stock
567 sold this month
from $2.80
Keystone SuperKleen 40 Evacuation Cleaner Powder, 2 Lbs
Keystone Industries
Keystone SuperKleen 40 Evacuation Cleaner Powder, 2 Lbs
010-3988
In stock
$15.86
Directa Hygoformic Bio Saliva Ejector
Directa
Hygoformic Bio Saliva Ejector
107-0405
In stock
$22.87

About amalgam separators

An amalgam separator is a collection device designed to capture and remove dental amalgam from the amalgam process wastewater of a dental facility. The EPA promulgated pretreatment standards in 2017 to reduce discharges of mercury from dental offices into publicly owned treatment works, and the regulation is codified at 40 CFR Part 441. Dental clinics are the main source of mercury discharges to those plants, and the EPA estimates dentists discharge approximately 5.1 tons of mercury to them each year. Once captured by a separator, mercury can be recycled.

A practice that places or removes amalgam must operate and maintain an amalgam separator and must not discharge scrap amalgam or use certain kinds of line cleaners. Under the EPA rule a separator must comply with the ANSI/ADA Specification 108 for Amalgam Separators or the ISO 11143 standard, in a version that requires at least a 95% removal efficiency. The ADA states the same figure: the EPA requires amalgam separators to achieve at least a 95% removal efficiency. The final rule became effective as of 14 July 2017, and the date for compliance was 14 July 2020.

A separator installed before 14 June 2017 may continue in use until 14 June 2027 if it is functioning properly and does not need to be replaced. The rule also allows a device other than an amalgam separator, provided it has a removal efficiency of at least 95 percent of the mass of solids from all amalgam process wastewater. A one-time compliance report documenting the separator, or the exemption, is filed with the practice’s Control Authority, which is either a local wastewater utility, a state environmental agency or a US EPA regional office.

How separators and their parts differ
  • Amalgam Separators — An amalgam separator is a collection device designed to capture and remove dental amalgam from the amalgam process wastewater of a dental facility.
  • General Repair & Replacement Parts — The collection containers and recycle kits that are replaced, rather than the separator.
How amalgam separators work

Amalgam separators remove amalgam particles from the wastewater through centrifugation, sedimentation, filtration, or a combination of any of these methods. Practically all amalgam separators on the market today rely on sedimentation because of its effectiveness and operational simplicity. The EPA puts the median efficacy of ISO-compliant amalgam separators on the market in the United States at 99.3 percent.

Mercury from dental amalgam in wastewater is present in both the particulate and dissolved form. A further process sometimes called polishing uses ion exchange to remove dissolved mercury, and the EPA says ion exchange will not be effective without first being preceded by a solids collector and an oxidation process. The data available to the EPA indicate that total additional mercury reductions with the addition of polishing are typically about 0.5 percent.

Solids collected by the separator may be a combination of dental amalgam, biological material from patients, and any other solid material sent down the vacuum line. The EPA identified three major technologies that capture dental amalgam waste, in addition to chair-side traps and vacuum pump filters: separators, ion exchange and wastewater containment systems.

What to look at when choosing and running an amalgam separator

Sizing: the separator must be sized to accommodate the maximum discharge rate of amalgam process wastewater.

Inspection: the separator is inspected in accordance with the manufacturer’s operating manual, to ensure proper operation and maintenance and to confirm that all amalgam process wastewater is flowing through the amalgam retaining portion. What running one involves, in the EPA’s own costing: visual inspection, replacement of the amalgam-retaining unit, separator maintenance and repair, recycling, and recordkeeping.

Containers: the amalgam retaining unit is replaced according to the manufacturer’s schedule, or when it has reached the maximum level at which the separator can still perform to the specified efficiency, whichever comes first. A separator that is not functioning properly must be repaired or replaced as soon as possible, and no later than 10 business days after the malfunction is discovered.

What comes out of it: amalgam collected in a separator is likely to be a hazardous waste under federal waste law because of the mercury and silver content of the amalgam. The EPA generally does not expect dental offices collecting amalgam waste to be above the very small quantity generator threshold. Several separator makers offer services that transport waste amalgam to facilities that separate mercury from the other metals and recycle it.

Records: documentation of each inspection, of container replacement, of the dates collected amalgam was picked up or shipped, and of any repair or replacement, is kept for a minimum of three years.

Sources: EPA: Dental Effluent Guidelines · EPA 40 CFR Part 441, Dental Office Point Source Category · ADA Oral Health Topics: Amalgam Separators and Waste Best Management Practices · EPA 822-S-17-002, Frequently Asked Questions on the Dental Office Category Rule (Nov 2017) · EPA final rule, Effluent Limitations Guidelines and Standards for the Dental Category (82 FR 27154, 14 June 2017)