Skip to content
Free shipping over $10Order by 3 PM ET, ships the same day 30-day returns, no restocking fee
(814) 299-9937 · Mon–Fri 9am–5pm ET
Polydentia ID-Rings
PolydentiaShips in 3 business days

Polydentia ID-Rings · Assorted, 120 pcs

SKU 107-0826MFR# 5320

Polydentia ID-Rings belongs to our storage accessories range, made by Polydentia.

This page carries 11 color options: Brown, White, Yellow, Red, Blue, Green, Black, Orange and 3 more.

Find it on our Instruments shelf, under Cassettes, Storage & Care.

Orders placed before 3 PM ET ship the same day when the item is on our shelf (otherwise within 3 business days), and ground shipping is free over $10.

Product

Manufacturer
Polydentia
Manufacturer #
5320
Item code
107-0826

Catalog path

Marketplace
Clinical
Category
Instruments

Ordering

Status
Ships in 3 business days

More from Cassettes, Storage & Care

Stocked in the same subcategory.

View all 15
RMH3 Dental Front Surface Mirrors, Cone Socket — 12/Box
RMH3 Dental
Front Surface Mirrors, Cone Socket — 12/Box
2 sizes
In stock
19 sold this month
from $8.31
RMH3 Dental #23 Williams Expro (Explorer/Probe)
RMH3 Dental
#23 Williams Expro (Explorer/Probe)
057-0238
In stock
$2.80
RMH3 Dental Probes / Explorers
RMH3 Dental
Probes / Explorers
3 patterns
In stock
from $2.34
Keystone Fog Free Mirror Defogger, Mint, 1 Quart
Keystone Industries
Keystone Fog Free Mirror Defogger, Mint, 1 Quart
010-3972
In stock
$11.49
RMH3 Dental Extracting Forceps, US Pattern
RMH3 Dental
Extracting Forceps, US Pattern
15 numbers
In stock
25 sold this month
from $10.73

Questions

Which color options are on this page?

This page carries 11 color options: Brown, White, Yellow, Red, Blue, Green, Black, Orange and 3 more. Pick one to see its price, part number and stock.

When does it ship?

In-stock orders placed before 3 PM ET ship the same day; anything not on our shelf ships within 3 business days.Ground shipping is free over $10.

About storage accessories

Contaminated instruments are moved in a covered container that is puncture-resistant and leak-proof, and the CDC states that handling of loose contaminated instruments during transport should be kept to a minimum. For manual cleaning the CDC describes work-practice controls such as a long-handled brush, and never reaching into a tray or container holding sharp instruments that cannot be seen.

The CDC sorts patient-care items by the risk they carry: critical items penetrate soft tissue or bone and should always be heat sterilized, while semicritical items touch mucous membranes and most of them can and therefore should be heat sterilized too. After cleaning, instruments are dried, inspected, then wrapped, packaged or placed into container systems before heat sterilization, because wet instruments can compromise the packaging.

The CDC names wrapped perforated instrument cassettes, peel pouches of plastic or paper and sterilization wraps as the materials that keep instruments sterile through transport and storage. ISO 11607-1 is the international standard for that packaging: materials and sterile barrier systems meant to keep a sterilized device sterile until the point of use.

How the cassettes, storage and care items differ
  • Trays and cassettes — The container the instruments stay in from the sink to the sterilizer to the shelf.
  • Storage and organization — Where the finished package waits; the CDC discourages storing unwrapped semicritical instruments at all.
  • Storage accessories — The rings, markers and covered containers used around a tray, rather than the sterile barrier itself.
  • Clamps and holders — The part that holds the instruments down, not the tray or the wrap around them.
  • Case organizers — Fixes the order of the set inside the case; it is not itself the sterile barrier.
  • Sharpening — Restores a cutting edge rather than cleaning or storing, and a sharp edge has been associated with more tactile sensitivity and less lateral pressure on the instrument.
  • Bur blocks — Holds small rotary instruments rather than hand instruments.
What to look at when choosing a cassette or storage item

Match to the cycle: packaging materials allow the sterilizing agent to penetrate and hold sterility afterwards, and the CDC states they should be designed for the type of sterilization process being used.

Indicators: an internal chemical indicator belongs in every package, with an external one when the internal indicator cannot be seen from outside.

Room for the load: hinged instruments are processed open and unlocked.

Labelling: before a package goes into the sterilizer the CDC asks for at least the sterilizer used and the cycle or load number on the label.

Standard: ISO 11607-1 covers packaging and sterile barrier systems wherever medical devices are placed in sterile barrier systems and sterilized, in industry and in health care facilities alike.

Safe handling: a covered, puncture-resistant and leak-proof container for transport, and no hand reaching into a container of unseen sharp instruments.

Sources: CDC: Best Practices for Sterilization in Dental Settings · CDC: Guidelines for Infection Control in Dental Health-Care Settings — 2003 (MMWR 52(RR-17)) · ISO 11607-1:2019, Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems · Periodontal instrumentation technique: an exploratory analysis of clinical outcomes and financial aspects, 2023 (Br Dent J) · Nimmanon et al. 2022, Scanning electron microscope analysis of working ends of standard and modified Gracey curettes (J Indian Soc Periodontol)