Skip to content
Free shipping over $10Order by 3 PM ET, ships the same day 30-day returns, no restocking fee
(814) 299-9937 · Mon–Fri 9am–5pm ET
Beyes Dental M200 Highspeed Handpieces
Beyes DentalShips in 3 business days

Beyes Dental M200 Highspeed Handpieces · Maxso M200E Smart · Single Spray, Non-Optic · M4

SKU 056-0000MFR# HP2105
Model Maxso M200E Smart · Single Spray, Non-Optic
Backend M4
M4$116.00 Beyes QD

Beyes M200 non-optic highspeed handpiece with a 45-degree head, M4 backend, rear exhaust and stream water cooling. Catalog code HP2010.

Beyes Dental M200 Highspeed Handpieces is an endodontic handpiece from Beyes Dental.

This page carries 3 model options: Maxso M200E Smart · Single Spray, Non-Optic, M200 · Triple Spray, Non-Optic, M200 45-Degree · Rear Exhaust, Stream Water, Non-Optic. This page carries 2 backend options: M4, Beyes QD.

Find it on our Endodontics shelf, under Apex Locators, Pulp Testers & Endo Motors.

Orders placed before 3 PM ET ship the same day when the item is on our shelf (otherwise within 3 business days), and ground shipping is free over $10.

Product

Manufacturer
Beyes Dental
Manufacturer #
HP2105
Item code
056-0000

Catalog path

Marketplace
Clinical
Category
Handpieces
Subcategory
Handpieces

Ordering

Status
Ships in 3 business days

More from Handpieces

Stocked in the same subcategory.

View all 19
Jinme Jinme A1-M4 Single Water, No Light, Big Head, and Push Button
Jinme Apple Dental
Jinme Jinme A1-M4 Single Water, No Light, Big Head, and Push Button
065-0000
In stock
$51.54
Jinme Jinme Green-CA Screw Type, External Water
Jinme Apple Dental
Jinme Jinme Green-CA Screw Type, External Water
065-0005
In stock
$24.99
RMH3 Dental Poli Lube Handpiece Lubrication Oil
RMH3 Dental
Poli Lube Handpiece Lubrication Oil
2 sizes
In stock
11 sold this month
from $26.53
Jinme Jinme Green-SH External Water
Jinme Apple Dental
Jinme Jinme Green-SH External Water
065-0006
In stock
$24.32
Jinme Red-TU Triple Water, No Light, Big Head, and Push Button
Jinme Apple Dental
Jinme Red-TU Triple Water, No Light, Big Head, and Push Button
065-0001
In stock
$59.99

Questions

What is Beyes Dental M200 Highspeed Handpieces used for?

Beyes M200 non-optic highspeed handpiece with a 45-degree head, M4 backend, rear exhaust and stream water cooling.

Which model and backend options are on this page?

This page carries 3 model options: Maxso M200E Smart · Single Spray, Non-Optic, M200 · Triple Spray, Non-Optic, M200 45-Degree · Rear Exhaust, Stream Water, Non-Optic. This page carries 2 backend options: M4, Beyes QD. Pick one to see its price, part number and stock.

When does it ship?

In-stock orders placed before 3 PM ET ship the same day; anything not on our shelf ships within 3 business days.Ground shipping is free over $10.

About handpieces and motors

A dental handpiece is a hand-held device, powered by air, water, electricity or a belt, intended to prepare cavities for restorations and to clean teeth; it may include a foot controller for speed and direction of rotation, or a contra-angle attachment for areas that are hard to reach. ISO 14457 is the international standard for handpieces and motors used on patients, and it takes in straight and angle handpieces, high-speed air turbine handpieces, air motors, electrical motors and prophy handpieces. Endodontic motors drive the file in rotation or in reciprocation, and let the user set direction, angle, speed and torque.

Root canal treatment is meant to stay inside the root canal space, so the length of the canal has to be established first. An electronic apex locator is one accepted way of finding that length; the other common way is a radiograph, which carries superimposed structures, geometric distortion and radiation exposure. A pulp tester answers a different question: it evaluates the vitality of the pulp by passing a high-frequency current through an electrode to stimulate the nerve tissue inside the tooth, and the FDA classes it as Class II (21 CFR 872.1720).

An endo motor turns the file. Reciprocating motion was introduced as an alternative to continuous rotation because it puts less cyclic and torsional stress on the instrument, which lowers the risk of fracture. Motors come corded and cordless, and let the user set reciprocation direction, angle, speed and torque. Some motors have an electronic apex locator built in, which can be used on its own or while the canal is being shaped.

How the types on this shelf differ
  • Handpieces & Motors — The powered part that turns a bur or a file, as against the parts and consumables that fit it. Handpieces and attachments are semicritical items that must be heat sterilized between patients according to the maker’s instructions.
  • Endo Equipment Parts & Accessories — Fits an endodontic unit; it is not the unit itself. Sonic activation uses much lower frequencies, roughly 150 to 300 Hz, with polymer tips that oscillate to stir the irrigant.
  • Pulp Vitality Testers — Reads whether the nerve in the pulp responds, not how long the canal is. A scoping review of pulpotomy studies found markedly higher positive response rates with electric pulp testing than with cold testing.
  • Root Canal & Caries Locators — Shows where something is rather than how the tooth responds. Published studies disagree about the dyes: some report that they overstain and lead to unnecessary removal of sound dentin, others that without them carious tissue goes undiagnosed.
  • Apex Locators — Measures length; the pulp tester on the same shelf measures nerve response. A scoping review concluded that the accuracy of these devices is acceptable in most cases but that a radiograph alongside remains advisable to confirm the measurement.
  • Measuring & Marking Instruments — Reads or holds a measurement by hand, with no power supply and no electrode.

Pages for curing lights, canal preparation gels, files, posts, irrigating devices and scaler tips also sit on this shelf; those types have homes of their own elsewhere.

What to look at when choosing

Reading conditions: a scoping review identified twenty factors that affect how accurate an apex locator reading is, among them canal curvature and length, tooth type, file size and alloy, apical patency, resorption, perforation, irrigants and medicaments.

Motor settings: corded and cordless motors differ in what they let you set, and reciprocation was introduced to reduce cyclic and torsional stress on the file. Some motors carry an apex locator inside, usable on its own or during instrumentation.

Pulp testing: cold, heat and electric tests all read nerve response rather than the blood supply of the pulp, and none has consistently achieved ideal sensitivity and specificity across clinical situations.

Patients with implanted cardiac devices: the ADA reports that at a distance of at least 15 centimetres, interference from ultrasonic scalers, apex locators and other dental devices is not considered likely to present any clinical risk. In laboratory tests apex locators were a low risk for light electromagnetic interference, though one in-vivo study induced a symptomatic interruption of pacing.

Sources: Factors influencing the accuracy of electronic apex locators: a scoping review (Dent Res J, PMC12252002) · FDA 21 CFR 872.1720, Pulp tester · Osaki et al. 2026, In vitro assessment of integrated apex locator systems (J Clin Exp Dent) · FDA 21 CFR 872.4200, Dental handpiece and accessories · ISO 14457:2017, Dentistry — Handpieces and motors · ADA Oral Health Topics: Infection Control and Sterilization · Comparative in vitro evaluation of sonic, passive ultrasonic, and laser-activated irrigation (BMC Oral Health, PMC13589355) · Pulp sensibility assessment following permanent tooth pulpotomy: a scoping review (Front Dent Med, PMC13639861) · Diagnostic accuracy of individual and multimodal pulp sensibility tests (Cureus, PMC13539165) · FDA 21 CFR 872.1740, Caries detection device · Iglesias-Poveda et al. 2025, Caries detector dyes and laser fluorescence systems: a scoping review (Front Dent Med) · FDA 21 CFR 872.4565, Dental hand instrument · ADA Oral Health Topics: Cardiac Implantable Devices and Electronic Dental Instruments