Parkell 5mL Dispensing Gun for use with Predicta Bulk and Predicta Core materials. Catalog code S620.
Parkell Dispensing Guns is a dispensing guns & delivery system from Parkell.
This page carries 4 gun options: 10 mL Split-Cartridge, 50 mL Split-Cartridge, 10:1 Cartridge, Predicta Bulk + Core 5 mL.
Find it on our Restorative & Cosmetic shelf, under Mixing Tips & Dispensing.
Orders placed before 3 PM ET ship the same day when the item is on our shelf (otherwise within 3 business days), and ground shipping is free over $10.
Product
- Manufacturer
- Parkell
- Manufacturer #
- S343
- Item code
- 108-0136
Catalog path
- Marketplace
- Clinical
- Category
- Restorative & Cosmetic
- Subcategory
- Mixing Tips & Dispensing
Ordering
- Status
- Ships in 3 business days
More from Mixing Tips & Dispensing
Stocked in the same subcategory.




Questions
What is Parkell Dispensing Guns used for?
Parkell 5mL Dispensing Gun for use with Predicta Bulk and Predicta Core materials.
Which gun options are on this page?
This page carries 4 gun options: 10 mL Split-Cartridge, 50 mL Split-Cartridge, 10:1 Cartridge, Predicta Bulk + Core 5 mL. Pick one to see its price, part number and stock.
When does it ship?
In-stock orders placed before 3 PM ET ship the same day; anything not on our shelf ships within 3 business days.Ground shipping is free over $10.
About dispensing guns
A dispensing gun holds the cartridge and presses out both parts together; cartridges come in sizes such as 50 ml and 10 ml, each used with the gun made for it.
Two-part materials in automix cartridges are pressed out with a dispensing gun through a mixing tip, a static mixer fixed to the end of the cartridge. The gun is matched to the cartridge by size and mixing ratio, which makers mark on the gun, for example DS-50 with 1:1 and 2:1.
How dispensing guns and mixing tips differ
- Dispensing guns and delivery systems — The reusable part, chosen by cartridge size and mixing ratio.
- Mixing tips and applicators — The disposable part: used mixers are discarded and the cartridge is resealed with its original cap.
What to look at when choosing
Fit: makers' instructions name the tip for each cartridge by colour and size, such as a yellow tip for a 50 ml cartridge and a brown tip for a 10 ml one. Material should come out easily through a mixer of the right size; one maker warns that excessive force can rupture the cartridge or break the gun.
Needle tips: some static mixers carry a built-in metal needle tip of a stated gauge, such as 17 or 19 gauge, for more precise placement.
First material out: makers instruct users to express a small amount onto a pad first, to ensure an even mix of base and catalyst.
Sources: Parkell, Predicta Bioactive Bulk instructions for use · Parkell, Cinch instructions for use · Parkell, Absolute Dentin instructions for use · Pulpdent, ACTIVA BioACTIVE dual cure instructions for use