Skip to content
Free shipping over $10Order by 3 PM ET, ships the same day 30-day returns, no restocking fee
(814) 299-9937 · Mon–Fri 9am–5pm ET
Pac-Dent Impression Gun Holders
Pac-DentShips in 3 business days

Pac-Dent Impression Gun Holders · 4 guns

SKU 103-0442MFR# 410-4
Holds 4 guns
2 guns$29.90 4 guns$42.97
The Pac-Dent 2-Impression gun holder, 1 per box. MARK3 Temporary Crown & Bridge Material - A2, 50ml 10:1 Cartridge and 10 Tips. Setting time: intraoral 2-3 minutes. Full set: 6-7 minutes. Catalog code 410-2.

Product

Manufacturer
Pac-Dent
Manufacturer #
410-4
Item code
103-0442

Catalog path

Marketplace
Clinical

Ordering

Status
Ships in 3 business days

More from Mixing Tips & Guns

Stocked in the same subcategory.

View all 41
Kromopan Color-Changing Alginate, Dust-Free, Fast Set
Lascod
Kromopan Color-Changing Alginate, Dust-Free, Fast Set
6 packs
In stock
188 sold this month
from $10.70
EcoPression VPS Bite Registration Material, 2 × 50 mL Cartridges
MN Health
EcoPression VPS Bite Registration Material, 2 × 50 mL Cartridges
3 sets
In stock
547 sold this month
from $9.20
EcoPression VPS Impression Material, 4 × 50 mL Cartridges
MN Health
EcoPression VPS Impression Material, 4 × 50 mL Cartridges
3 bodys · 2 sets
In stock
292 sold this month
from $18.00
RMH3 Dental VPS Impression Materials, 50 mL Cartridges
RMH3 Dental
VPS Impression Materials, 50 mL Cartridges
3 materials · 3 sets
In stock
229 sold this month
from $16.08
Parkell Blu-Mousse VPS Bite Registration
Parkell
Blu-Mousse VPS Bite Registration
4 sets · 2 scents · 2 packs
In stock
19 sold this month
from $60.00

Questions

What is Pac-Dent Impression Gun Holders used for?

The Pac-Dent 2-Impression gun holder, 1 per box.

Which holds options are on this page?

This page carries 2 holds options: 2 guns, 4 guns. Pick one to see its price, part number and stock.

When does it ship?

In-stock orders placed before 3 PM ET ship the same day; anything not on our shelf ships within 3 business days.Ground shipping is free over $10.

About dispensing guns & syringes

An impression dispensing gun holds the cartridge of impression material and presses both parts out together, each cartridge size with the gun made for it. Cartridges come in sizes such as 50 ml and 10 ml. The gun is matched to the cartridge by size and mixing ratio, which makers mark on the gun, for example DS-50 with 1:1 and 2:1. In one published technique a light body material was injected over the abutments with an automatic mixing syringe with a tip attached.

Two-part impression and restorative materials are mixed one of three ways: by hand, through a static mixer, or by a machine that mixes them dynamically. A review calls auto-mixed, cartridge-based materials a notable development, and gives two reasons: it removes the spatulation step and the operator errors that go with it, and it cuts the number of voids in the impression by a factor of four to five against mixing by hand. A cartridge is pressed out with a dispensing gun through a mixing tip, a static mixer fixed to the end of the cartridge.

How mixing tips, intraoral tips, guns and bowls differ
  • Mixing Tips — The disposable part: used mixers are discarded and the cartridge is resealed with its original cap.
  • Intraoral Tips — Added after the mixer, to reach into the mouth.
  • Dispensing Guns & Syringes — The reusable part, chosen by cartridge size and mixing ratio. Material comes out easily through a mixer of the right size; one maker warns that excessive force can rupture the cartridge or break the gun.
  • Mixing Bowls & Dishes — For material mixed by hand, where a cartridge and tip are not involved.
What to look at when choosing

Fit: makers' instructions name the tip for each cartridge by colour and size, such as a yellow tip for a 50 ml cartridge and a brown tip for a 10 ml one. Some static mixers carry a built-in metal needle tip of a stated gauge, such as 17 or 19 gauge, for more precise placement.

First material out: makers instruct users to express a small amount onto a pad first, to ensure an even mix of base and catalyst.

Gloves: sulfur from natural latex gloves can contaminate the platinum catalyst of a vinyl polysiloxane and hold up its set, and the end of a mixing tip is one of the things a review names as not to be touched with latex gloves on.

Where the voids come from: a review lists mixing of base and catalyst, loading of the tray or syringe, the syringing itself, and working past the working time.

Sources: Addition Silicone Impressions in Fixed Prosthodontics: Clinical Standpoints, 2023 (PMC10517288) · Parkell, Predicta Bioactive Bulk instructions for use · Parkell, Cinch instructions for use · Parkell, Absolute Dentin instructions for use · A Comparative Study to Evaluate the Accuracy of Various Spacer Thickness for Polyvinyl Siloxane Putty-wash Impression Techniques, 2020 (PMC7887158) · Cervino et al. 2018, Alginate Materials and Dental Impression Technique: A Current State of the Art (Mar Drugs) · Pulpdent, ACTIVA BioACTIVE dual cure instructions for use