Skip to content
Free shipping over $49Order by 3 PM ET, ships the same day 30-day returns, no restocking fee
(814) 299-9937 · Mon–Fri 9am–5pm ET
Sold out
DirectaSold out

Directa Calaject Stand for Handpiece, HF60555M1

SKU 107-0443MFR# HF60555M1
$154.83 · Sold out

The Directa Stand for handpiece is a anesthetics product supplied by Directa for local anesthesia delivery. Catalog code HF60555M1.

Directa Calaject Stand for Handpiece, HF60555M1 belongs to our delivery system accessories & parts range, made by Directa. Manufacturer part number HF60555M1.

Find it on our Anesthetics shelf, under Injectable & Sedation.

Orders placed before 3 PM ET ship the same day when the item is on our shelf (otherwise within 3 business days), and ground shipping is free over $49.

Product

Manufacturer
Directa
Manufacturer #
HF60555M1
Item code
107-0443

Catalog path

Marketplace
Clinical
Category
Anesthetics

Ordering

Status
Sold out

More from Injectable & Sedation

In stock in the same subcategory. Not the same product — check the specs before you swap.

View all 11
Dharma Iolite 20% Benzocaine Topical Anesthetic Gel, 1.12 oz
Dharma
Iolite 20% Benzocaine Topical Anesthetic Gel, 1.12 oz
8 flavors · 2 formulas
In stock
312 sold this month
$5.00
Cook-Waite Type 1.8 cc Aspirating Syringe
RMH3 Dental
Cook-Waite Type 1.8 cc Aspirating Syringe
001-0054
In stock
$9.48
GingiPak GINGICaine Topical Anesthetic Gel, 20% Benzocaine
GingiPak
GINGICaine Topical Anesthetic Gel, 20% Benzocaine
8 flavors · 2 packs
In stock
from $10.06
Keystone CORA-CAINE (36-4GR)
Keystone Industries
Keystone CORA-CAINE (36-4GR)
010-0006
In stock
$73.10
Directa Cartridge barrels (autoclavable), pack of 3 pcs.
Directa
Cartridge barrels (autoclavable), pack of 3 pcs.
107-0441
In stock
$22.52

Questions

What is it used for?

The Directa Stand for handpiece is a anesthetics product supplied by Directa for local anesthesia delivery.

When does it ship?

In-stock orders placed before 3 PM ET ship the same day. An item we don't keep on the shelf shows its own ship-by date on its page, and you can cancel it for a full refund until it ships.Ground shipping is free over $49.

About delivery system accessories & parts

The body of a cartridge syringe is the metal part that holds the disposable, previously filled glass carpule and takes the needle. ISO 9997 covers cartridge syringes used in dentistry of the non-aspirating, aspirating and self-aspirating types, and sets requirements for syringes with ISO metric thread sizes while noting that syringes with imperial thread sizes also exist. The parts on this shelf are sold to fit one maker’s delivery system.

This shelf holds equipment for delivering anaesthetic and sedation gas; no anaesthetic drug sits on it. A cartridge syringe is a device intended to inject anaesthetic agents, built as a metal syringe body into which a disposable, previously filled glass carpule of anaesthetic is placed; a needle is attached to the body and the carpule is activated by partly inserting the plunger. The FDA puts the cartridge syringe in Class II with special controls. A literature review puts the number of anaesthetic cartridges used for dental treatment in the United States at approximately 300 million a year.

Cartridges are made to an international standard: ISO 11499 sets performance requirements for single-use dental cartridges of 1.0, 1.7, 1.8 and 2.2 ml nominal capacity and lists the overall dimensions that make a cartridge fit a dental cartridge syringe. Each single-use cartridge carries two indelible bands indicating the name and concentration of the anaesthetic ingredient and of the vasoconstrictor. The ADA notes that colour-coding is a useful adjunct for anaesthetic identification.

How the kinds on this shelf differ
  • Computerized Delivery Systems — The injection speed is set by the machine rather than by hand. A review lists what separates one such system from another: whether the anaesthetic cartridge sits in the main unit, the speed and mode of injection, whether aspiration is possible, the weight, and ease of infection management.
  • Delivery System Accessories & Parts — The reusable part of the instrument rather than the single-use cartridge or needle. A cartridge fits a syringe because the standard lists the overall dimensions that make it fit.
  • Nitrous System Accessories — Parts of a gas delivery system rather than of an injection: scavenging apparatus collects excess anaesthetic, analgesic or trace gases from the patient’s breathing system and conducts them out of the area through an exhaust system. The ADA notes that chronic occupational exposure of several hours a week to unscavenged nitrous oxide has been associated with adverse health effects.
What to look at when choosing

Fit between the parts: the needle standard covers single-use injection needles used in dental cartridge syringes complying with ISO 9997.

Aspiration: ISO 9997 covers non-aspirating, aspirating and self-aspirating cartridge syringes, and on a computerized system whether aspiration is possible is one of the points that differ between devices.

Weight and handling: a review notes that these devices are held still for long periods, and that one too heavy to operate easily may move while the needle is inside the tissue, which can break the needle.

Changing the cartridge: devices differ in how the cartridge is changed, and where it sits outside the main unit it is changed much as on a conventional syringe.

For a gas system, the ADA describes testing the pressure connections for leaks every time the system is first turned on and each time a gas cylinder is changed, and inspecting the reservoir bag, tubing, masks and connectors for wear, cracks, holes or tears before the first use of the day.

Sources: FDA 21 CFR 872.6770, Cartridge syringe · Ho et al. 2021, Adverse effects following dental local anesthesia: a literature review (J Dent Anesth Pain Med) · ISO 11499:2014, Dentistry — Single-use cartridges for local anaesthetics · ADA Oral Health Topics: Anesthesia and Sedation · Kwak et al. 2016, Computer-controlled local anesthetic delivery for painless anesthesia: a literature review (J Dent Anesth Pain Med) · ISO 9997:2020, Dentistry — Cartridge syringes · ADA Oral Health Topics: Nitrous Oxide · FDA 21 CFR 868.5160, Gas machine for anesthesia or analgesia (CFR 2025, govinfo) · FDA 21 CFR 868.5590, Scavenging mask (CFR 2025, govinfo) · FDA 21 CFR 868.5430, Gas-scavenging apparatus (CFR 2025, govinfo) · ISO 7885:2010, Dentistry — Sterile injection needles for single use